Rexroth proportional directional valve 3DREP6C-21/25EG24N9K4/M
How to order: R900978110 3DREPE6A-2X/45EG24N9K31/F1M R901195874 3DREP6B-21=25EG24N9K4/M-674=00 3DREPE-6C-21/25EG24N9K31/A1M 3DREPE-6C-20/25EG24N9K31/F1M 3DREP6C-2X=25EG24N9K4-M=00 3DREP6C-20=25EG24/9K31/F1M=00 3DREP6C-21=25EG24N9K4/M=00 3DREP6A-11/25A24NZ4M 3DREP 6 A-2X/25EG24N9K4/M+Z4 3DREP6B-21=25EG24N9K4/M-674=00 3DREP6C-2X/25EG24N9K4/M 3DREPE6C-2X/6EG24N9K31/FIV 3DREPE6C-20=25EG24K31/A1M=00 R900962045 3DREP6A-20/45EG24N9K4/M 3DREPE6C-2X/25EG24N9K31/F1M=00 R900962045 3DREP6A-20/45EG24N9K4/M R900962045 3DREP6C-20/45EG24N9K4/M 3DREPE6C-20-25ED24N9K 31/FLM- 3DREPE6C-2X/25EG24K31/AIM 3DREP6C-13/25A24NZ4W 3DREP6C-11/Z5A 24NZ4M 3DREP6C-20- 3DREP6C-2X/25EG24N9K4/M 3DREP6C-2X/25EG24N9K4/M 3DREPE6C-20/25EG24N9K31/F1V=00 3DREP 6C-12/25A 24N9 Z 4MR 3DREP 6C-12/25A 24N9 2 4MR 3DREP 6C-14/25A 24 N9 Z 4M 3DREP6C-10R/25A24HZ4 3DREP-6C-12/25A24NZ4M 3DREP-6C-12/25A24NZ4M 3DREP6C-14/25A 24N 9K4M 3DREP6C-14/25A 24N 9K4M 3DREPE6C-2X/25EG24K31/F1M-00 3DREP6C-11/25AG24NZ4M 3DREP6C-11/25AG24NZ4M 3DREPE6C-20/25EG24N9K31/F1V=00 3DREP6C-2X/25EG24N9K4/M 3DREP6C-2X/25EG24N9K4/M 3DREP6C-20=25EG24N9K4/M=00 3DREP6C-2X/25EG24N9K4/M 3DREP6C-14/25A24K4M 3DREP6C-14/25A24K4M 3DREP6C-20=25EG24N9K4/M=00 3DREP6C-20/25EG24N9K4/M00 3DREP6C-20/25EG24N9K4/M 3DREP6C-20-25EG24N9K4/M 3DREP6A-2X/45EG24N9K4 Original Rexroth 3DREP6C-21=25EG24N9K4/M=00 proportional valve for sale One type involves switch control, where the option is either fully open or fully closed, and the flow rate is either at its maximum or minimum, with no intermediate state. Examples include ordinary electromagnetic straight-through valves, electromagnetic directional valves, and electro-hydraulic directional valves. The other type is the continuous control valve port, which can be opened to any desired degree to control the flow rate. These valves can be manually controlled, such as throttle valves, or electronically controlled, such as proportional valves and servo valves. The purpose of using a proportional valve or servo valve is to achieve throttling control of flow through electronic control (of course, pressure control can also be achieved through structural modifications). Since it is throttling control, there will inevitably be energy loss. The difference between servo valves and other valves is that the energy loss is greater, as it requires a certain flow rate to maintain the operation of the pre-stage control oil circuit Solenoid valves: 4WE6, 4WE10, 4WE16; Electro-hydraulic valves: 4WEH10H, 4WEH16, 4WEH25,